Free Member Listed Since 2008 |
|
 SAMGOR TECHNOLOGY China |
| Home |
 |
| Company Info |
 |
| Trade Offers |
| |
- Selling Offers(23)
|
 |
| Share your thoughts |
| |
- Write a review
- Recommend to your friends
|  |
| Contact Us |
 |
| Language |
| | - English
|
 |
| | |
|
Selling Offers
showing 1-20 of 23 | First | Prev | 1 | 2 | Next | Last
| Test Fields and Shielded Rooms |
 (Product Photo) |
| | TYPE JF Partial Discharge Shielding Room (Factory Building) is suitable for the partial discharge experiment and impact test in different voltage band (110KV, 220KV, 500KV, 750KV,1000KV) of cable, voltage transformer, transformer, switch, and power station etc.
Since 1993, TYPE JF Shielding Room (Factory Building) has got the approval of the international companies such as Heafely and.... | | |
|
| Origin: | China |
|
| CBB60 Metallized Polypropylene Film Capacitor |
 (Product Photo) |
| | SPECIFICATIONS:
1.Reference Standard: GB 3667-1997
2.Climatic Category: 40/070/21
3.Capacitance Tolerance: ±5%; ±10%
4.Dissipation Factor (Tangent of Loss Angle): d0.002 (100Hz)
5.Insulation Resistance: e3000s
6.Voltage Proof: 1.75Un (2s)
7.Endurance Test:
`Test conditions
Temperature: 70
Applied Voltage: 1.25Un
Duration: 600h
aAfter the test
Capacitance Change: ”C/Cd3% | | |
|
| Origin: | China |
|
| CBB95 High Frequency Capacitor |
 (Product Photo) |
| | SPECIFICATIONS:
1.Reference Standard: Q/KJX 14-2004
2.Capacitance Range: 0.01¼F^100¼F
3.Capacitance Tolerance: 0^10%
4.Rated Voltage: 1kV^100kV
5. Rated Frequency : 1kHz^500kHz
6.Dissipation Factor (Tangent of Loss Angle): d0.002 (1kHz, 20)
7.Insulation Resistance: RCe7500M©·¼F
8.Voltage Proof: 2.15Un a.c.; 4.3Un d.c., 2s
9.Operating Temperature Range:.... | | |
|
| Origin: | China |
|
| ASMJ(ASMR)-Filter Capacitor |
 (Product Photo) |
| | SPECIFICATIONS:
1.Reference Standard: GB/T 12747.1-2004
2.Capacitance Tolerance: 0^+5%
3.Rated Voltage: 0.25kV^3.0kV
4.Dissipation Factor (Tangent of Loss Angle):
d0.0015 (100Hz, 20)
5.Voltage Proof: 2.15Un, 2s
6.Insulation Resistance: pole and shell 3.6Un, 2s
7.Operating Temperature Range: -40^+50 | | |
|
| Origin: | China |
|
| CBB80A High Voltage AC Metallized Polypropylene Film Capacitor |
 (Product Photo) |
| | SPECIFICATIONS:
1.Reference Standard: Q/KJX 4-2004
2.Capacitance Range: 0.5¼F^1¼F
3.Capacitance Tolerance: ±5%
4.Rated Voltage: 1400Va.c.
5.Dissipation Factor (Tangent of Loss Angle): d0.0008 (1kHz, 20)
6.Insulation Resistance: e10000M©
7.Voltage Proof: 4000Vd.c. (2s), 2100Va.c. (2s)
8.Expected Life:100000hours
9.Operating Temperature Range: -40^55 | | |
|
| Origin: | China |
|
| DGMJ(DKMJ, DZMJ), AGMJ AC Electric Locomotive Capacitor |
 (Product Photo) |
| | SPECIFICATIONS:
1.Reference Standard: IEC 61881-1999
2.Capacitance Range: 100¼F^10000¼F
3.Capacitance Tolerance: ±5%, (we can adjust according to your needs )
4.Rated Voltage: 600V^4000V
5.Dissipation Factor (Tangent of Loss Angle): d0.002 (50Hz, 20)
6.Inductance:20^600nH, (according to your requirement we can handtailor lower inductive capacitor )
7. Expected Life.... | | |
|
| Origin: | China |
|
| CZ82 High Voltage Sealing Paper Dielectric Capacitor |
 (Product Photo) |
| | SPECIFICATIONS:
1.Reference Standard: SJ 1249-77
2.Climatic Category: 55/070/10
3.Capacitance Tolerance: ±5%; ±10%
4.Dissipation Factor (Tangent of Loss Angle): d0.01
5.Insulation Resistance: CRd0.22¼Fe10000M©
CR>0.22¼Fe2000s
6.Voltage Proof: URd15kV 2UR
URe20kV 1.5UR | | |
|
| Origin: | China |
|
| CH82 High Voltage Sealing Compound Capacitor |
 (Product Photo) |
| | SPECIFICATIONS:
1.Reference Standard: SJ 660-73
2.Rated Voltage: 2kV^100kV
3.Capacitance Range: 0.01¼F^10¼F
4.Climatic Category: 55/085/10
5.Capacitance Tolerance: 5%; ±10%
6.Dissipation Factor (Tangent of Loss Angle): d0.01
7.Insulation Resistance: CRd0.1¼F, e10000M©
CR>0.1¼F, e2000s
8.Voltage Proof: URd30kV, 1.5UR
UR>30kV, 1.2UR | | |
|
| Origin: | China |
|
| MKMJ Self-Healing High Voltage Pulse Capacitor |
 (Product Photo) |
| | SPECIFICATIONS:
1.Reference Standard: Q/KJX 001-2004
2.Capacitance Range: 10¼F^10000¼F
3.Capacitance Tolerance: 0^10%
4.Rated Voltage: 3kV^60kV
5.Dissipation Factor (Tangent of Loss Angle): d0.006 (1kHz)
6.Insulation Resistance: RCe7500M©·¼F
7.specific energye0.5 J/cm3
8.Expected Life:e10000 times
9.Charge and Discharge Frequency1^600 times/minute
10.... | | |
|
| Origin: | China |
|
| CBBM Laser, Pulse, Energy Storage Capacitor |
 (Product Photo) |
| | SPECIFICATIONS:
1.Reference Standard: Q/KJX 20-2004
2.Operating Temperature Range:
40^+70
3.Dissipation Factor (Tangent of Loss Angle): d0.002 (100Hz)
4.Insulation Resistance: R·Ce10000 M©·¼F
5.Voltage Proof: 1.1^1.5Un (5s)
6 charge frequencies3^200 times/s | | |
|
| Origin: | China |
|
| CHM-Pulse Capacitor |
 (Product Photo) |
| | SPECIFICATIONS:
1.Reference Standard: GB/T 4704-92
2.Capacitance Range: 0.01¼F^10000¼F
3.Capacitance Tolerance: 0^10%
4.Rated Voltage: 1kV^100kV
5.Dissipation Factor (Tangent of Loss Angle): d0.002 (100Hz, 20)
6.Insulation Resistance: Cd1¼F, Re10000M©
C>1¼F, RCe10000M©·¼F
7.Voltage Proof: 1.1Un^1.4Un, 2s
8.Operating Temperature.... | | |
|
| Origin: | China |
|
| SG4008Partial Discharge Measuring System |
 (Product Photo) |
| | The SG4008SG4012 is the effective solution for routine pass/fail partial discharge testing. It has the basic functions of an analog detector and meets all IEC and IEEE/ANSI standards for partial discharge testing. It’s a straightforward replacement for older analog detectors of any make or model. The SG4008SG4012 simply measures the level of PD and the applied test voltage. It’s.... | | |
|
| Origin: | China |
|
| SG4001 Partial Discharge Measuring System |
 (Product Photo) |
| | The SG4001is with rejecting interference capability and partial discharge test system. It can independently collect data from two channels or four channels and show result from two or four windows. It can use in all kinds of voltage grade and capacity transformer, power generator, instrument transformer, bushing, GIS, capacitor, CVT, power cables, switch, other high-voltage equipments..... | | |
|
| Origin: | China |
|
| RY2 Precision Test Cell forSolid Insulants |
 (Product Photo) |
| | This precision test cell measures the dielectric properties of solid insulants like paper, plastic foil, etc.
Basically the test cell consist of a heat able, shielded plate capacitor which is protected by a bell jar and can be evacuated and filled with protective gas. | | |
|
| Origin: | China |
|
| YL series STANDARD CAPACITOR |
 (Product Photo) |
| | he SF6 gas insulated standard capacitor is used together with a C and tan delta measuring bridge as the comparison standard leg of the bridge. It is used as Capacitance standard in measuring bridge Circuits to measure the dielectric dissipation Factor tan´, Further-more, It can be used as high-voltage capacitor for voltage divider circuits of high-voltage transformer test.
Highest.... | | |
|
| Origin: | China |
|
| Alternating Voltage AC Testing YDTW series |
 (Product Photo) |
| | Conventional AC test transformers are especially designed for testing objects of medium capacitance in the factory. These systems are particularly suited for tests requiring stable voltage even if the load changes during the testing (heavy corona, wet & pollution tests) or when the load is of inductive kind (inductive voltage transformers). The possibility to stack several of these.... | | |
|
| Origin: | China |
|
| SG7101 Precision Power Analyzer |
 (Product Photo) |
| | The precision power analyzer is mainly applied to measure all kinds of loss and impedance for electric equipments such as power transformer, generator, electric motor. SG7101 precision power analyzer is the only production, which has the same precision with Switzerland SG7101 power analyzer in national. At the same time it also can be used to test power transformer and electric motor.... | | |
|
| Origin: | China |
|
| Impulse Voltage Testing |
 (Product Photo) |
| | CDY series impulse test systems can be used to generate impulse voltages simulating lightning strokes and switching surges.
The stage energy is 2.5 kJ~1620kJ. Max. charging voltage is 100~7200kV.
Applications covered include testing according to IEC, ANSI/IEEE as well as other national standards. The basic system can be upgraded in various ways for special tests and for greater ease of.... | | |
|
| Origin: | China |
|
| SG2008 Precision Capacitance and Dissipation Bridge |
 (Product Photo) |
| | SG2008 Automatic 12kV Capacitance & Dissipation Factor Test Set is designed to measure dissipation( Dielectric Loss Angle tand tg´ ) or power factor ( cosÆ ) in heavy electromagnetic interference environment such as in power plants or substations. Also it can be used in laboratory for high accurate test. The test set is all-in-one structure: including precision digital.... | | |
|
| Origin: | China |
|
showing 1-20 of 23 | First | Prev | 1 | 2 | Next | Last
|